skip to Main Content

Hydro-S Heat Pump

£460.00£995.00 Plus 20% VAT

Rated 0 out of 5
(be the first to review)

**OUT  OF STOCK**

The Bosta Hydro-S Swimming Pool Heat Pumps are extremely efficient. economical and a very environmentally friendly way of heating your pool.

A wide range of heat output / kW models to choose from:– 3kW; 4.5kW; 7.5kW; 9.5kW; and 12kW.

Clear

Additional information

Weight 100 kg

Overview

why Choose a Heat Pump?

Simply because it’s inexpensive – to buy – to run – to install.

Realistically, in this country, all swimming pools whether above or in-ground, need heating to obtain the maximum use from the summer season. Having a pool in your garden may be aesthetically pleasing to the eye but unless the pool feels warm and inviting, the pool will not be used to its full potential. By investing in a Heat Pump, this can change!

Generally, the main heating systems available for swimming pools are Gas (LPG or Propane), Electric or Oil heaters. Some of these heaters can be beneficial from a cost point of view but tend to lose their appeal when it comes to installation costs.

A heat pump does not generate heat, it simply captures it and moves it from air to water thus, providing an efficient and environmentally friendly system for heating your swimming pool!

Hyro-S Features:

  • High efficiency coefficient up to 4,7
  • Automatic frost protection. When air temperature drops under 8°C, pump will turn off
  • Easy digital temperature control with LCD display
  • All functions are microprocessor controlled
  • Easy manual control
  • Quiet running with low sound rotary compressor, low noice fan
  • R410A gas for an environmentally friendly operations
  • Titanium heat exchanger resistant to salt and chlorine
  • Including drain and flow switch
  • Maximum pool volume depending on average outside temperature

Product Manual

Model Reference Table

Model: Heating Capacity A27/W27(kW): COP A27/W27: Input Power (kW): Max. Pool Size (m³): Connections:
Hydro-S 3 3.5 4.5 0.77 15 50mm
Hydro-S 5 4.5 4.4 0.97 20 50mm
Hydro-S 8 7.5 4.7 1.41 30 50mm
Hydro-S 10 9.5 4.6 1.61 45 50mm
Hydro-S 12 12 4.7 2.1 60 50mm

How Does A Heat Pump Work?

A Swimming Pool Heat Pump is a super efficient way of heating your Swimming Pool as it uses advanced refrigeration technology to capture the heat in the outside air and transfer it to your swimming pool water. It works in fact like a fridge in reverse. For every unit of electricity that you put in to run the compressor you will get approx. 4.6 units of heat out of the heat pump- so nearly 80% of the energy is FREE!

To heat your pool correctly you will need to run your filtration for a minimum of 12 hours a day throughout the season and use a solar cover when the pool is not in use.

1. Hydro-Pro Swimming Pool Heat Pumps are available in three styles:-

2. The Hydro-S range- ideal for above ground pools and heats pools for the Summer Season only

3. The Hydro-Pro range- will heat in-ground and above ground pools during an extended Summer Season, and operates down to -5°C.

4.The Hydro-Pro Inverter range- will work in lower temperatures down to -10°C, for an all year round solution

The energy is collected from the air outside and transferred to the pool water using the same technology that is used in a3. ir-conditioning units and fridges. For each single kW used by the Hydro-S heat pump, between 4 and 5kW are returned to the pool as heat.

Read the information in the instruction manual before connecting. It is compulsory that a qualified electrical technician must check or install the wiring. Connection made by unprofessional people may cause injury even death. The manufacturer shall not be responsible for the consequences of connection made by unqualified people or disregarding the manual.

Guides

2 Year PARTS & LABOR WARRANTY!

Unit

mode

  H-S 3 

H-S 5 

  H-S 8 

H-S 10 

H-S 12 

heating power input

kW

0.77

0.97

1.41

1.61

2.1

heating capacity (A27/W27)

kW

3.5

4.5

7.5

9.5

12.0

heating capacity (A15/W26)

kW

3.0

3.7

5.5

6.1

8.2

maximum volume (good insulation)

m3

15

20

30

45

60

running current

Amp

3.4

4.9

7.4

8.0

10.6

coeffiient (C.O.P.)  at A27/W27

4.5

4.4

4.7

4.6

4.7

coeffiient (C.O.P.)  at A15/W25

3.9

3.8

3.9

3.7

3.9

compressor

rotary

rotary

rotary

rotary

rotary

refrigerant

R410a

R410a

R410a

R410a

R410a

fan quantity

1

1

1

1

1

fan power input

W

68

68

80

80

120

fan rotate speed

RPM

830/870

830/870

830/870

830/870

830/870

fan direction

horiz.

horiz.

horiz.

horiz.

horiz.

noise level (10 metres)

dB (A)

37

37

39

39

43

water connection

mm

50

50

50

50

50

nominal water flow

m/h3

3.5

3.5

5.7

5.7

8.5

dimensions (L/W/H)

cm

75/29/50

75/29/50

93/35/55

93/35/55

100/36/62

unit shipping dimensions (L/W/H)

cm

85/33/54

85/33/54

106/38/59

106/38/59

112/38/66

net weight/ shipping weight

Kg

32/36

36/38

47/53

47/53

61/65

maximium current

A

4.1

5.9

8.9

9.6

12.8


Above Ground Pool Sizing (guideline only, based on 4 ft depth)

     Pool Size

    Gallons

    Litres

      Model

10′ Diameter 1000 3,800 Eco 3
12′ Diameter 1800 6,700 Eco 5

15′ Diameter

4400

20,000

Eco 8

18′ Diameter

6350

29,000

Eco 12

19′ x 12′

4900

23,000

Eco 10

23’ x 12’

5700

26,000

Eco 12

In-Ground Pool Sizing (guideline only, based on 4 ft depth)

 Pool Size

Gallons

Litres

 Model

20′  x 10′

5610

26,000

Eco 10

24′  x 12′

7000

30,000

Eco 12

28′  x 14′

9000

35,000

Eco 12

Diagrams

hydro s features diagram
hydro-s typical installtion

Specifications

Model: Hydro-S 3 Hydro-S 5 Hydro-S 8 Hydro-S 10 Hydro-S 12
Heating Capacity A27/W27(kW): 3.5 4.5 7.5 9.5 12
Heating Capacity A15/W15 (kW): 3.0 3.7 5.5 6.1 8.2
Input Power (kW): 0.77 0.97 1.41 1.61 2.1
COP A27/W27: 4.5 4.4 4.7 4.6 4.7
COP A15/W15: 3.9 3.8 3.9 3.7 3.9
Max. Volume (m³ / Gallons) 15 / 3,300 20 / 4,400 30 / 6,600 45 / 9,900 60 / 13,200
Current (Amps Running) 3.4 4.9 7.4 8.0 10.6
Voltage: 230v 230v 230v 230v 230v
Compressor: Rotary Rotary Rotary Rotary Rotary
Noise Level (1m) dB(A): 46 46 48 48 52
Refrigerant: R410a R410a R410a R410a R410a
Fan Direction: Horizontal Horizontal Horizontal Horizontal Horizontal
Water Connections: 50mm 50mm 50mm 50mm 50mm
Nominal Flow (m³/h): 2.5 2.5 2.5 2.6 3.5
Max. Pressure Loss (kPa): 12 12 12 12 15
Dimensions H x W x L (mm): 750 x 290 x 500 750 x 290 x 500 930 x 350 x 550 930 x 350 x 550 1000 x 360 x 620
Weight (Kg): 32 36 47 47 61

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Back To Top
×Close search
Search